  Kernel driver gl518sm
  =====================
  
  Supported chips:
    * Genesys Logic GL518SM release 0x00
      Prefix: 'gl518sm'
      Addresses scanned: I2C 0x2c and 0x2d
7f15b6646   Rudolf Marek   [PATCH] I2C: docu...
8
9
10
    * Genesys Logic GL518SM release 0x80
      Prefix: 'gl518sm'
      Addresses scanned: I2C 0x2c and 0x2d
0ea6e6112   Justin P. Mattock   Documentation: up...
11
      Datasheet: http://www.genesyslogic.com/
7f15b6646   Rudolf Marek   [PATCH] I2C: docu...
12
13
14
  
  Authors:
          Frodo Looijaard <frodol@dds.nl>,
be2a608bd   John Anthony Kazos Jr   documentation: co...
15
          Kyösti Mälkki <kmalkki@cc.hut.fi>
7f15b6646   Rudolf Marek   [PATCH] I2C: docu...
16
          Hong-Gunn Chew <hglinux@gunnet.org>
7c81c60f3   Jean Delvare   Update Jean Delva...
17
          Jean Delvare <jdelvare@suse.de>
7f15b6646   Rudolf Marek   [PATCH] I2C: docu...
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
  
  Description
  -----------
  
  IMPORTANT:
  
  For the revision 0x00 chip, the in0, in1, and in2  values (+5V, +3V,
  and +12V) CANNOT be read. This is a limitation of the chip, not the driver.
  
  This driver supports the Genesys Logic GL518SM chip. There are at least
  two revision of this chip, which we call revision 0x00 and 0x80. Revision
  0x80 chips support the reading of all voltages and revision 0x00 only
  for VIN3.
  
  The GL518SM implements one temperature sensor, two fan rotation speed
  sensors, and four voltage sensors. It can report alarms through the
  computer speakers.
  
  Temperatures are measured in degrees Celsius. An alarm goes off while the
  temperature is above the over temperature limit, and has not yet dropped
  below the hysteresis limit. The alarm always reflects the current
  situation. Measurements are guaranteed between -10 degrees and +110
  degrees, with a accuracy of +/-3 degrees.
  
  Rotation speeds are reported in RPM (rotations per minute). An alarm is
  triggered if the rotation speed has dropped below a programmable limit. In
  case when you have selected to turn fan1 off, no fan1 alarm is triggered.
  
  Fan readings can be divided by a programmable divider (1, 2, 4 or 8) to
  give the readings more range or accuracy.  Not all RPM values can
  accurately be represented, so some rounding is done. With a divider
  of 2, the lowest representable value is around 1900 RPM.
  
  Voltage sensors (also known as VIN sensors) report their values in volts.
  An alarm is triggered if the voltage has crossed a programmable minimum or
  maximum limit. Note that minimum in this case always means 'closest to
  zero'; this is important for negative voltage measurements. The VDD input
  measures voltages between 0.000 and 5.865 volt, with a resolution of 0.023
  volt. The other inputs measure voltages between 0.000 and 4.845 volt, with
  a resolution of 0.019 volt. Note that revision 0x00 chips do not support
  reading the current voltage of any input except for VIN3; limit setting and
  alarms work fine, though.
  
  When an alarm is triggered, you can be warned by a beeping signal through your
  computer speaker. It is possible to enable all beeping globally, or only the
  beeping for some alarms.
  
  If an alarm triggers, it will remain triggered until the hardware register
  is read at least once (except for temperature alarms). This means that the
  cause for the alarm may already have disappeared! Note that in the current
  implementation, all hardware registers are read whenever any data is read
  (unless it is less than 1.5 seconds since the last update). This means that
  you can easily miss once-only alarms.
  
  The GL518SM only updates its values each 1.5 seconds; reading it more often
  will do no harm, but will return 'old' values.